Codian MCU 4200 Series Remote Management API
2.9 participant.disconnect
Parameter Type Comments
conferenceName string
autoAttendantUniqueId string
participantName string
participantProtocol string
participantType string
Participant identification as described above.
This call causes the MCU to tear down its connection to the specified participant, if such a connection
exists. This is different from “participant.remove” above because in the case of configured participants it
does not remove the configuration (thus allowing later re-connection with “participant.connect”) and in
the case of ad hoc participants it does not remove the record of the previous connection.
2.10 device.query
There are no parameters passed with this method call. The method response returns the following:
Parameter Type Comments
currentTime dateTime.iso8601 The system’s current time.
restartTime dateTime.iso8601 The date and time at which the system was last restarted.
2.11 participant.enumerate
Parameter Type Comments
enumerateID(optional) string The value returned by the last enumeration call, if omitted a
new enumeration is started.
returns:
Response Type Comments
enumerateID(optional) string The value which should be used in the next call to get the
next set of data
and an array called “participants” of structs which contain